  1. The most important advantages of efficient and modern wall-mounted (urgent) water heaters compared to old and large water heaters equipped with tank Include: optimal consumption of fuel, high safety, use of modern technology (technology), transportation, easy installation, without need to primary waste of time in heating water, non heating water after consumption, non occupation of useful space of kitchen and non waste of energy for hot water reservation.      
  2. In Butane wall-mounted (urgent) water heaters, the models labeled with letter I are type of ionizer and the models labeled with letter I are equipped with fan, and those labeled with letter “if” indicates ionizer models equipped with fan and those labeled with letter “rs” is water heater model of closed combustion chamber .
  3. Ionizer models are selected for the zones having salts and residues in the water and for the zones having no urban gas.
  4. In wall-mounted water heaters, Ionizer Models, while opening water tab, turn smart sparkler system without need to permanent pilot and this causes advantages such as 30% saving in gas consumption due to removal of permanent pilot, improvement of energy category (label) in comparison with models of permanent pilot, decrease of sedimentation of heat exchanger and no need to periodical service of water heater pilot. 
  5. Fan in Butane wall-mounted water heaters equipped with fan, it is possible to immediately discharge gases resulting from system combustion, for the buildings suffering from chimney problem (even by less diameter of chimney). 
  6. The advantage of water heater of “rs” gas of closed combustion chamber is nonuse of internal oxygen at home for combustion. 
  7. All Butane wall-mounted water heaters in addition to ability of performance, with low water pressure (Bar 0.2), having local standards and CE European Quality Standard, are equipped with temperature adjustment valve, outlet water quantity, flame adjust ability on volume and continuous basis, safety valve, heating switch on the exchanger, modular smart flame system (gradual), functionality with urban gas and liquid gas.      
  8. Maximum length of hot water pipe from water heater to the farthest consumable hot water valve for small models (000,18) is 6 M., and for models (000.21) is 8 M. and for models (000.24) is 10 M.
  9. All kinds of Butane wall-mounted water heaters are provided with 3-year warranty by Butane Co.
  10. Butane Mfg. and Industrial Co. has been the most successful and famous Mfg. brands in the field of wall-mounted water heaters in the country by manufacturing, supplying and exporting millions of all kinds of gas-fuel wall-mounted water heaters during past decades by enjoying wide after-sale-services network of its products.

The points should be taken into consideration after purchasing Butane Wall-mounted Water Heater

  1. Butane wall-mounted (urgent) water heaters are easily used by liquid gas.
  2. Installatoin of water cooler at bathroom, toilet, bedroom and space spaces unequipped with suitable air-conditioner is emphatically forbidden. 
  3. All Models of Butane Water Heaters need suitable chimney and using them without chimney is forbidden. 
  4. Butane wall-mounted water heaters, insertion of water heater flame on short position , causes decrease of sedimentation and depreciation of system and increase of water heater longevity.
  5. Gas-fuel devices at the time of performance produce poison, odorless, colorless and invisible gas of monoxide carbon (CO)that in case of entrance to the house causes bite, headache, dizziness, vomit and finally causes poisoning and death, therefore, installation of chimney as well as suitable air-conditioning at installation place of gas-fuel devices is obligatory.
  6. Gas hose used for liquid gas and urban gas is different and maximum permissible length of gas hose for transfer of urban gas to device is 120 Cm. and for transfer of liquid gas is 150 Cm.
  7. Installation of outlet of chimney beside cooler or window is forbidden.  
  8. Coldness of chimney indicates incorrect performance and penetration of pollution to the residential space.
  9. At least 3 M. should be considered for height of chimney of ordinary gas-fuel devices.
  10. Installation of Cap H minimizes negative effects of wind on flow of smoke inside the chimney and chimney operates correctly.
By typewall-mounted
ModelMaximum Heating Capacity
(Kcal/hr)
Hot water supply at ∆T 25˚CMaximum Gas Consumption
(M3/hr)
Exhaust Diameter(Cm)PilotDimensions (cm)Net Weight
(Kg)
Price($)
HeightWidthDepth
B41081220091.515Permanent54.925.622.78.2102
B-311218000122.115Permanent683624.812.8120
B-31152100013.62.415Permanent683624.813125
B-311824000162.715Permanent73.84526.516140
B-4208 i1220091.510Ionizer5525.622.78.2111
B-3212 i18000122.115Ionizer683624.812.8132
B-3215 i2100013.62.515Ionizer683624.813135
B-3218 i24000162.715Ionizer73.84626.516150
B3315 if2100013.62.58 (دودکش ویژه)Ionizer683624.815165
B3318 if24000162.88 (دودکش ویژه)Ionizer73.84526.518.5175
B5418 rs22360152.7510(6) Double WallIonizer65.436.224.119200

Write a review

ModelMaximum Heating Capacity
(Kcal/hr)
Hot water supply at ∆T 25˚CMaximum Gas Consumption
(M3/hr)
Exhaust Diameter(Cm)PilotDimensions (cm)Net Weight
(Kg)
Price($)
HeightWidthDepth
B41081220091.515Permanent54.925.622.78.2102
B-311218000122.115Permanent683624.812.8120
B-31152100013.62.415Permanent683624.813125
B-311824000162.715Permanent73.84526.516140
B-4208 i1220091.510Ionizer5525.622.78.2111
B-3212 i18000122.115Ionizer683624.812.8132
B-3215 i2100013.62.515Ionizer683624.813135
B-3218 i24000162.715Ionizer73.84626.516150
B3315 if2100013.62.58 (دودکش ویژه)Ionizer683624.815165
B3318 if24000162.88 (دودکش ویژه)Ionizer73.84526.518.5175
B5418 rs22360152.7510(6) Double WallIonizer65.436.224.119200