Fan Coil Unit Selection Tips :

  • Fan coil units can supply cooled air in the summer and heated air in the winter by running the air through copper coils passing cold or hot water.
  • Typically, fan coils are often used in cases where we need to separate the control over the temperature in different spaces and to prevent the exchange or displacement of air and contaminants between areas.
  • Floor-mounted fan coil units are available with capacities typically ranging between 200 and 1200 Cubic Feet per Minute (CFM) and in both vertical and horizontal models.
  • Ceiling-mounted fan coil units that come in both cabinet and exposed models are available in a range of capacities from 200 to 1200 CFM and are installed over the drop ceiling (usually at the entrance to the room).

fan coil

  • Further, ceiling-mounted, cassette fan coil units are available that have their coils installed above the drop ceiling and can be controlled by both a thermostat and using a remote control.
    As far as airflow direction is concerned, the cassette fan coil unit may come in one-way or four-way models and can be of either two-pipe or four-pipe types.
    fan coil
  • Moreover, the recently-introduced, wall-mounted fan coil units have found popularity with construction contractors.fan coil
  • Ducted fan coil units are also available in a range of capacities from 600 to 2000 CFM.fan coil
  • Before placing an order for a fan coil, please learn whether the pipes will be installed on the left or the right.

Important Factors in Selecting a Fan Coil System

  1. Type: Fan coil units are available in different types, including floor-mounted, horizontal, sloped-top, built-in units, ceiling-mounted, four-way cassette, wall-mounted (similar to a mini-split), and ducted fan coil units that can be selected depending on the case of usage.
  2. Capacity: The first factor as regards selecting a fan coil is its heating or cooling capacity. When calculating the fan coil capacity—according to the total refrigeration load (both sensible and latent) of the space—base your calculati...

Fan Coil Unit Selection Tips :

  • Fan coil units can supply cooled air in the summer and heated air in the winter by running the air through copper coils passing cold or hot water.
  • Typically, fan coils are often used in cases where we need to separate the control over the temperature in different spaces and to prevent the exchange or displacement of air and contaminants between areas.
  • Floor-mounted fan coil units are available with capacities typically ranging between 200 and 1200 Cubic Feet per Minute (CFM) and in both vertical and horizontal models.
  • Ceiling-mounted fan coil units that come in both cabinet and exposed models are available in a range of capacities from 200 to 1200 CFM and are installed over the drop ceiling (usually at the entrance to the room).

fan coil

  • Further, ceiling-mounted, cassette fan coil units are available that have their coils installed above the drop ceiling and can be controlled by both a thermostat and using a remote control.
    As far as airflow direction is concerned, the cassette fan coil unit may come in one-way or four-way models and can be of either two-pipe or four-pipe types.
    fan coil
  • Moreover, the recently-introduced, wall-mounted fan coil units have found popularity with construction contractors.fan coil
  • Ducted fan coil units are also available in a range of capacities from 600 to 2000 CFM.fan coil
  • Before placing an order for a fan coil, please learn whether the pipes will be installed on the left or the right.

Important Factors in Selecting a Fan Coil System

  1. Type: Fan coil units are available in different types, including floor-mounted, horizontal, sloped-top, built-in units, ceiling-mounted, four-way cassette, wall-mounted (similar to a mini-split), and ducted fan coil units that can be selected depending on the case of usage.
  2. Capacity: The first factor as regards selecting a fan coil is its heating or cooling capacity. When calculating the fan coil capacity—according to the total refrigeration load (both sensible and latent) of the space—base your calculations on the capacity at medium speed. Consult the following table for estimating the required capacity of the fan coil to be installed in a residential building in a temperate climate such as in Tehran (the capacity of fan coil units is often reported in CFM, which is the cubic feet of air supply from the fan per minute).
    fan coil
  3. The fan coil capacities presented in the table for different floor areas are estimates at design indoor temperature and maximum fan speed. At medium speed, the correction factor for the air supply of fan coil units is approximately 0.8 relative to top speed and around 0.85 for cooling and heating capacity. You can contact our consultants at DamaTajhiz for further information.
    fan coil
    fan coil
  4. Dimensions:The selected fan coil must be fit for installation in the space planned for it. Dimensions are particularly important for ceiling-mounted and cassette fan coil units (notice: re-check all dimensions before placing an order).
  5. Coil: Often, three rows of 3/8 in copper tubes are used to make the coil, however, using a double-row configuration with 1/2 in tubes will reduce pressure drop in the working fluid, in addition to improving the efficiency of the equipment. In some cases, to allow for the simultaneous supply of hot and cold air during the day, or for the different spaces in a luxury apartment, fan coil units with two separate coils are used (one for maintaining a flow of cold water from the chiller, another for the supply of hot water from the boiler). These are known as four-pipe fan coil units.
    • In other words, two-pipe fan coil units are equipped with only one coil, one supply line, and one return line, whereas their four-pipe counterparts feature two coils, and consequently, one pair of supply–return lines for hot water, and another for cold water.
    • Four-pipe fan coil units supply both hot and cold air to the space during the day, as well as allowing for heating one part of the building while cooling another.
  6. Casing: It is best for the fan coil unit to come with an integrated casing to prevent rattling noises made by loose parts with vibration.
  7. Motor: The fan coil motor must be low-noise, multi-speed, and equipped with reliable ball bearings to keep the noise from the working equipment below 35 dB.
  8. Fan: It is best to use metal centrifugal fans in the fan coil unit for maintaining dynamic balance during long periods of operation to ensure perfect air supply. High-quality polyamides are also acceptable materials that are much cheaper. Non-metal fans are not recommended for climates with cold winters that require maintaining the temperature of the water circulating a central system around 80 °C, for it can deform the fan in the long run.
  9. Working Pressure: Considering that the water pressure in the coil will exceed 6 bar in buildings taller than 15 stories, this factor is of great importance in selecting a fan coil system for a high-rise.
  10. Appearance: One shall also note how the fan coil unit—particularly, the floor-mounted models—would appear as a component of the interior design.
  11. Control: At startup, the electric motor of the fan coil unit can be adjusted both manually and automatically but the best approach—particularly, for ceiling-mounted, wall-mounted, and cassette fan coil units—is to use a three-stage, two-season automatic thermostat and a three-way electric valve.
  • Although floor-mounted fan coil units traditionally come with manual On/Off switches and speed controllers, installing an automatic room thermostat is essential to control the function of fan coil units and optimize energy consumption. Basically, the room thermostat installed at 140 cm from the floor, away from the supply air blowing from the fan coil unit and direct sunlight, serves to switch the unit on and off and to control the fan speed.
  • In a supplemental method using a slow-opening two-way electric valve or a three-way motor-operated valve and by implementing a bypass route, the command from the thermostat installed in the space can be used to regulate the circulation of cold or hot water supply to the fan coil unit, thus allowing to accurately adjust the cold or hot air supply by the controller.

Price: The price is a determining factor in the purchase of any product. However, when selecting a fan coil system, the thermal comfort of the residents, durability, noise, efficiency, capacity, and appearance come first.

fan coil
Technical Notes on Implementing the Fan Coil System

  1. To calculate the required flow rate of cold water for cooling, divide the total refrigeration load (in BTU) in each room of the building by 5000 (or divide it in kcal/hr by 1250). Accordingly, 1/2 in tubes are used for both cold and hot supply and return lines to 200 CFM fan coil units, whereas 3/4 in tubes are used in 300 and 400 CFM units, 1 in tubes are used in 1000 CFM units, and 1 1/4 in tubes are used in fan coil units of up to 1200 CFM and ducted fan coil units of up to 1800 CFM.
  2. Installing a flow switch on the evaporator output path (chilled water) to the cooling coil of the air conditioning equipment (including fan coil and air handling units) is necessary for commanding the chiller to stop when circulator pumps in the refrigeration circuit shut down.
  3. Given the higher heating capacity of fan coil units than radiators of similar sizes, in older buildings, installing a fan coil system instead of radiators (only for heating) is only possible if the piping runs through the floor (and not in the wall supporting the unit).
  4. Given the significance of the dynamic balance of the aeration fan as regards the performance of fan coil units and their direct impact on the durability of the ball bearing motor, make sure to have the fan mounted in place perfectly horizontally to maintain the dynamic balance of the fan.
  5. To facilitate the maintenance of the air conditioning equipment, it is essential to install a cut-off valve at both the inlet and outlet of the unit with a fitting union nut (same size as the branch pipe).
  6. It is essential to install a 1/2 in drain line on the tray under the coil to collect the moisture distilled on the coil of the unit in the summer.

Placing an Order and Warranties for Fan Coil Unit :

  • Offering best price guarantee for all products, the prices for fan coil units presented by DamaTajhiz are up-to-date and discount-included (see Best Price Guarantee at DamaTajhiz.com).
  • At DamaTajhiz.com, we provide all the information you need, as well as guaranteed unbeatable prices, for several models of fan coil units from reliable manufacturers, with original warranties, to bring you the thrill of an ideal, intelligent purchase.

best price


See more, make a better choice

1CFM =  28.32 L/min
1K Cal = 4 BTU

fan coil

Less
More
Showing 1 - 24 of 44 items

Filter by

Price
$ 0 $ 440
Manufacturers
more... less

Short Introdution

Since 2003, DamaTajhiz Online Store has been active in the supply of all types of heating, ventilation, and air conditioning (HVAC) equipment by management of Mr. Majid Zavvarian to meet needs of construction projects and consumers in the Middle East.

Investigating new methods of e-commerce and looking ahead to the future, DamaTajhiz Online Store designed its way of success as the first startup for selling installation equipment in Iran and the Middle East in 2004 by launching the most comprehensive specialized shopping website for all types of heating, ventilation, and air conditioning (HVAC), pool, sauna, and spa bath equipment.


Show More

Filter by:

News

Visit our blog