New Gold Iran Wall-mounted Package (LG) Expand

Gold Iran Wall-mounted Package (LG)

LG LG

New

Gold Iran Wall-mounted Heating Packages (LG) with England design and Technology, equipped with European parts exist in two types of Pioneer and Prestige...

More details

$ 637

International shipping + Insurance

Best price guarantee

Secure payment

Purchasing Guide for Gold Iran Wall-mounted Package (LG)

  1. All Gold Iran Wall-mounted Packages (LG) are double-exchanger and equipped with fan.
    Gold Iran Wall-mounted Heating Packages (LG) Models are equipped with large LCD with capability of weekly planning and also equipped with auxiliary devices including water softener filter, 3 M. of aluminum chimney pipe, 4 metal hoses, and two valves.
  2. Water pump incorporated at Gold Iran Wall-mounted Heating Packages with capability of water transfer up to height of 6 M. made of Denmark Grundfos.
  3. Installation devices, tubs and fittings of Gold Iran Wall-mounted Heating Packages (LG) despite other Wall-mounted gaseous packages, shall be delivered along device free of charge.
  4. For approximate calculation of BTU of required package, multiply area   of residential apartment by 150 (kilocalories) and area   of office buildings by 100 (kilocalories). (For example, you are recommended to use 21000-kilocalorie package for residential apartment with an area   of 140 Sqm.).
  5. In case the package has been installed at open space and or package chimney has been constructed in the form of L (L-shaped) (it means part of chimney path has been executed horizontally, use of fan run package for easy passage of smoke and ignition gases is obligatory.
  6. Gold Iran Wall-mounted Heating Packages (LG) is equipped with furnished with antiice protection. This system is only active when, firstly, package is turn on, secondly, water pressure in the package occurs at least for one time, thirdly, package gas is connected, however, the best option is non-installation of package in the locations where it is impossible to freeze water in the winter.
  7. Use of fan run package with double-Wall-mounted chimney (Coaxial) which is more confirmed, provides the ground for supplying airflow required for ignition of package by inner wall of chimney from outside an apartment and oxygen and wetness of inside an apartment is not reduced.
  8. Double-exchanger packages are used under the conditions in which consumed water contains hardness (salts) and or apartment's area   exceeds 120 M.
  9. According to safety and technical standards of Gas Co., a separate chimney should be directly executed up to roof of building for each Gold Iran gaseous Wall-mounted heating package. Using joint chimney is not permissible.
  10. According to Topic 17 of National Construction Code (2011) min. area   confirmable for installation of package at (office or residential) apartment is 64 Sqm., otherwise incorporation of fresh air valve for suitable ignition of package installation location is obligatory.
  11. Gold Iran Wall-mounted Heating Packages (LG) are provided with 2-year warranty and 15 years of after-sale-services.

The points should be taken into consideration after purchasing Gold Iran Wall-mounted Package (LG)

  1. After purchasing, for use of free of charge installation services, and warranty of Gold Iran Wall-mounted package, contact permissible call Nos. inserted on the carton of package (Please do not open carton before attendance of the authorized after-sale-services agent)
  2. According to safety and technical standards of Gas Co., a separate chimney should be directly executed up to roof of building for each Gold Iran Gas-fuel Wall-mounted heating package. Using joint chimney is not permissible
  3. Regarding head (pressure) of small circulator pump incorporated in all kinds of wall-mounted chiller packages, generally maximum length of piping from wall-mounted package to the latest location of chiller radiator should not be more than 35 m. 
  4. Generally anti-freezing system in heating packages, is active only when, firstly, package is plugged, secondly, water pressure inside package at least is an atmosphere, thirdly, package is connected to town gas, but however the best options is non installation of package in the locations where it is impossible to freeze water in the winter.  
ModelMaximum Thermal PowerPackage's DimensionsThermal efficiencyMaximum Electric ConsumptionNet Weight (kg)Price($)
KWKcal/hrHeightLengthWidthWØV
P282-F282400072403393%130122038637
P242-F242200072403393%125122036622
P262-F262400072.540.332.591-93%125122036536
P302-F302800082.748.834.591-92%130122042568

Write a review

Gold Iran Wall-mounted Package (LG)

Gold Iran Wall-mounted Package (LG)

MODELMaximum Cooling Capacity (Btu/hr)Maximum Heating Capacity (Btu/hr)Electric ConsumptionInternal panel's Dimensions(mm)Internal panel'sWeight (kg)Fan maximum aeration volume(m3/min)maximum sound intensity (db/A)PRICE($)
VØWidthDepthHeight
CB181800018000220
240
188.24526.02616.536---
CB242400024000220
240
188.24526.02618.036---
UB303000030000220
240
1118.24529.83326.536---
UB363600036000220
240
1118.24529.83332.042---
UB424200042000220
240
1123.05938.05238.042---
UB484800048000220
240
1123.05938.05240.044---
UB606000060000220
240
1123.05938.04950.046---
UB363600036000220
240
3118.24529.83332.042---
UB424200042000220
240
3123.05938.05238.042---
UB484800048000220
240
3123.05938.05240.044---